Lab
5.3.5 Cable Tester - Wire Map
Estimated time: 45 min.
Objectives:
- Demonstrate skill with a cable tester more advanced than a
simple continuity/pin-out tester
- Use the wire mapping features of the tester to check for opens
and shorts with UTP cable
- Perform wire mapping on cables, detecting faults that are not
detectable with simple continuity measuring devices such as
crossed and split pairs
Background:
In this lab you will learn the wire mapping features of the
Fluke 620 LAN CableMeter (or its equivalent). Wire maps can be very
helpful in troubleshooting cabling problems with UTP cable. Wire
maps are not used with coaxial cable since there is only one wired
and no map is needed. A wire map allows the network technician to
verify which pins on one end of the cable are connected to which
pins on the other end. With an understanding of the proper wiring
connections, you can determine when a cable is wired improperly,
depending on its intended use. You will learn how to use a cable
tester to check for the proper installation of Unshielded Twisted
Pair (UTP) Category 5 (CAT 5) according to TIA/EIA-568 cabling
standards in an Ethernet network. You will test different cables
using all four pairs to determine some problems that can occur from
incorrect cabling installation and termination.
The cabling infrastructure (or cable plant) in a building is
expected to last at least 10 years. Cabling related problems are one
of the most common causes of network failure. The quality of cabling
components used, the routing and installation of the cable and
quality of the connector terminations will be the main factors in
determining how trouble-free the cabling will be.
Tools / Preparation:
Prior to starting the lab, the teacher or lab assistant should
have several correctly wired CAT 5 cables (both straight thru and
crossover) to test. There should also be several CAT 5 cables
created with problems such as poor connections and split pairs to
test. Cables should be numbered to simplify the testing process and
to maintain consistency. A cable tester should be available that can
test at least continuity, cable length and wire map. Work
individually or in teams. The following
resources will be required:
- CAT 5 straight-wired cables of different colors.
- CAT 5 crossover-wired cable (T568A on one end and T568B on the
other )
- CAT 5 straight-wired cables with open wire connections in the
middle or one or more conductors shorted at one end of different
colors and different lengths.
- CAT 5 straight-wired cable with a split pair mis-wire.
- Cable Tester (Fluke 620 LAN CableMeter or similar) to test
cable length, continuity, wire map
Related Research Web Sites:
Step 1 - Set the Advanced Cable Tester for the Desired Cable.
These instructions pertain to the Fluke 620 LAN CableMeter. Turn
the rotary switch selector on the tester to the WIRE MAP position.
Press the SETUP button to enter the setup mode and observe the LCD
screen on the tester. The first option should be CABLE: Press the UP
or DOWN buttons until the desired cable type of UTP is selected. Press
ENTER to accept that setting and go to the next one. Continue pressing
the UP/DOWN arrows and pressing ENTER until the tester is set to the
following cabling characteristics.
Tester Option |
Desired Setting |
CABLE: |
UTP |
WIRING: |
10BASE-T or EIA/TIA
4PR |
CATEGORY: |
CAT 5 |
WIRE SIZE |
AWG 24 |
CAL to CABLE? |
NO |
BEEPING: |
ON or OFF |
LCD CONTRAST |
From 1 thru 10
(brightest) |
Step 2. Setup the Cable to be Tested
For each cable to be tested use the following procedure, place the
near end of the cable into the RJ-45 jack labeled UTP/FTP on the
tester. Place the RJ-45-RJ-45 female coupler on the far end of the cable
and then insert the Cable Identifier into the other side of the
coupler. The coupler and the cable identifier are accessories that
come with the Fluke 620 LAN CableMeter.
Step 3 – Perform Wire Map Testing
Using the tester Wire Map function and a Cable ID Unit, you can
determine the wiring of both the near and far end of the cable. The
top set of numbers displayed on the LCD screen is the near end and the
bottom set is the far end. Perform a Wire Map test on each of the
cables provided and fill in the following table based on the result
for each CAT 5 cable tested. For each cable, write down the number and
color, whether the cable is straight thru or crossover, the tester
screen test results and what you think the problem is.
Cable No.
|
Cable Color
|
How cable is wired (straight-thru
or crossover)
|
Tester Displayed Test Results (Note: refer to the
Fluke manual for detailed description of test results for wire map)
|
Problem
Description
|
1
|
|
|
Top:
Bot:
|
|
2
|
|
|
Top:
Bot:
|
|
3
|
|
|
Top:
Bot:
|
|
4
|
|
|
Top:
Bot:
|
|
5
|
|
|
Top:
Bot:
|
|
LAB 5.3.5 – CABLE
TESTER - WIRE MAP- ANSWERS
Step 1. Set the Advanced Cable Tester for the Desired cable
These instructions pertain to the Fluke 620 LAN Cablemeter. Turn the
rotary switch selector on the tester to the WIRE MAP position. Press the
SETUP button to enter the setup mode and observe the LCD screen on the
tester. The first option should be CABLE: Press the UP or DOWN buttons
until the desired cable type of UTP is selected. Press ENTER to accepts
that setting and go to the next one. Continue pressing the UP/DOWN
arrows and pressing ENTER until the tester is set to the following
cabling characteristics.
Tester
Option
|
Desired
Setting
|
CABLE:
|
UTP
|
WIRING:
|
10BASE-T
or EIA/TIA 4PR
|
CATEGORY:
|
CAT
5
|
WIRE
SIZE
|
AWG
24
|
CAL
to CABLE?
|
NO
|
BEEPING:
|
ON
or OFF
|
LCD
CONTRAST
|
From
1 thru 10 (brightest)
|
Step 2. Setup the Cable to be Tested
For each cable to be tested use the following procedure, place the
near end of the cable into the RJ-45 jack labeled UTP/FTP on the tester.
Place
the RJ-45-RJ-45 female coupler on the far end of the cable and then insert
the Cable Identifier into the other side of the coupler. The coupler and
the cable identifier are accessories that come with the Fluke 620 LAN
CableMeter:
Step 3 – Perform Wire Map Testing
Using the tester Wire Map function and a Cable ID Unit, you can
determine the wiring of both the near and far end of the cable. The top
set of numbers displayed on the LCD screen is the near end and the
bottom set is the far end. Perform a Wire Map test on each of the cables
provided and fill in the following table based on the result for each
CAT 5 cable tested. For each cable, write down the number and color,
whether the cable is straight thru or crossover, the tester screen test
results and what you think the problem is. (Your answers may vary)
Cable
No.
|
Cable
Color
|
How
cable is wired
(straight-thru
or crossover)
|
Tester
Displayed Test Results
(Note:
refer to the Fluke manual for detailed description of test results
for wire map)
|
Problem
Description
|
1
|
Red
|
Straight-thru
|
Top:
1 2 3
6 4 5
7 8 ID
Bot:
1 2 3 6
4 5 7
8 #1
|
Wire
is OK for a straight-thru cable
|
2
|
Blue
|
Straight-thru
|
Top:
1 2 3
6 o
ID
Bot: 1 2
3 6
#1
|
Open
(o means wire no. 2
open)
|
3
|
Yellow
|
Straight-thru
|
Top:
2 3
1
6
ID
Bot:
#1
|
Short
(wires 2 & 3 touching - near end)
|
4
|
Green
|
Straight-thru
|
Top:
1 3
2 6
ID
Bot: 1 3
2 6
#1
|
Split
Pair
|
5
|
Orange
|
Crossover
|
Top:
1 2 3
6 4 5
7 8 ID
Bot:
3 6 1
2 4 5
7 8 #1
|
Wire
is OK for a crossover cable
|
|